201212301102454.jpg (28.72 KB, 下載次數(shù): 2)
下載附件
保存到相冊
2015-7-24 14:33 上傳
故障現(xiàn)象: 三無(燈亮)
機芯: 飛利浦解碼OM88**(大屏幕)
機型: 2502D,2516B,2516D,2516DI,2516BI,2580DB,2510G,AT2575,2575D,
2515DZ,2580GI,2580G,2588DB,2511DI,2511D,2511DR,2511DZ,
2575DI,AT2515DZ,AT2590I,AT2590,AT2580D,AT2575D,AT2575DI,
AT2575DZ,AT2575F,AT2588D,AT2539,2939D,2939DR,2965D,2989D,
2913D,2975,2956D,2927D,2915DZ,2988DB,2916D,2988D,2980G,
2980GI,2980DB,2975D,2910G,2910DZ,2910D,2911,2911D,2911DI,
2911DZ,2980D,2988DF,2988DI,2975DI,AT2975D,AT2980D,AT2980DB
,2539D,2539DR,2539DI,3406D,3433D,3433DZ,3409D,3416,3416D,
3416DI,3418D,3416D(F),3438D,3480GI,3488GI,3460D,3488D,
34D106,AT3480DZ,AT3486DI,AT3460D,AT3416D(F),AT3488DZ,
2988G,2988D-F,2911Z,AT2990,AT2915DZ,AT2990I,AT2975F,
AT2975I,AT2988D,AT3480GI,3811DI,2589D,AT2556,AT2988,
AT2988DB,AT2956B,AT2911DZ,AT2915,AT2939,AT2956,AT2975Z,
AT2986Z,AT2575I,AT2586,3488BD,AT3486DZ
檢修過程: 機型:3498GH 故障現(xiàn)象:兩指示燈亮,三無 分析與檢修:開機顯像管燈絲亮,用萬用表測IC405 TDA8351場塊(9)腳供電電壓,結(jié)果無電壓。管機測R461電阻3.3Ω,阻值很大,拆下測量電阻已開路,更換IC405和R461電阻,故障排除。
故障板名稱: 主板
故障元件位號: IC405和R461
處理措施: G更換IC405和R461
圖片: 無
|